Year: 2000
Operating Hours: 4400
Main drive motor LAK4225-A, 210 kW DC, rated current 420A
(LAK4225-A is a modern direct current motor)
Starting current is limited to the rated current 420A
Main fuse on incoming power line should be minimum 630A (due to included starting equipment for conveyor belts)
General information on the cutting system:
The rotor is equipped with welded on replaceable wear plates for extra-long service life between repairs. The tool holders are welded on to the rotor and the cutting tools are bolted on to the holders for quick and trouble free replacement/ repair. No welding is required.